Home › Nefit error codes › Boiler › Error code 6C 306

Nefit Boiler Error Code 6C 306

Call a professionalReviewed November 2026Checked against manufacturer documentation
What this code means
6C 306: An ionisation current was measured after the burner had gone out: the boiler still sees a flame that should not be there

Code 6C 306 means the boiler still measures a flame signal while the burner is already out. That can be a dirty ignition unit, but also a gas block that does not close properly. Because this concerns gas safety, an installer must always check it; do not keep resetting.

Also shown as: 6C

Applies to: Nefit ProLine and TrendLine condensing boilers

Fix level
Call a professional
The checks on this page are preliminary. The likely fix involves a part, wiring or the control board.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Ignition unit, Gas control block
Parts are model-specific; see the note below before ordering.

Common causes

  1. Ionisation part of the ignition unit dirty or damaged
  2. Gas control block does not close fully, so gas keeps leaking through
  3. Moisture or dirt causes a false flame signal

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Note the full code and reset the boiler once.
  2. If the code stays or returns straight away, switch the boiler off and close the gas tap at the boiler.
  3. Call a CO-certified installer; a flame signal after shutdown must always be investigated inside the boiler.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

This code usually points to a faulty part, wiring or the control board on a Nefit boiler. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 6C 306, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Repair or replace?

This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.

Parts that may be involved

Ignition unitGas control block

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 6C 306

What does 6C 306 mean on a Nefit boiler?

6C 306 means: An ionisation current was measured after the burner had gone out: the boiler still sees a flame that should not be there. Code 6C 306 means the boiler still measures a flame signal while the burner is already out. That can be a dirty ignition unit, but also a gas block that does not close properly. Because this concerns gas safety, an installer must always check it; do not keep resetting.

Can I fix Nefit 6C 306 myself?

Only the preliminary checks. Code 6C 306 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.

How do I clear Nefit 6C 306?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Nefit boiler codes